Taylor K-1767ChemWorld is a distributor of Taylor Technologies Test Kits and Reagents. Order directly online and save today.
DROP TEST SALT WATER (1 drop = 20, 40, 100, 200, or 800 ppm)
COMPONENTS:
1 x 4078 Pipet, Graduated, 3 mL (0.5 mL div.),
plastic
1 x 5091 Instruction
1 x 9198O Sample Tube, Graduated, 25 mL, plastic
w/cap and orange dot
1 x R-0630-C Chromate Indicator, 2 oz, DB
1 x R-0706-C Silver Nitrate Reagent, 2 oz, DB.
NOTE: When sulfite content of sample water to be tested exceeds 10 ppm,
the sulfite should be oxidized to prevent interference in test.
A 25 mL water sample is first adjusted to the appropriate pH, then
1 mL (or 24 drops) of R-0649 3% Hydrogen Peroxide Solution (sold
separately) is added and thoroughly mixed. Continue with the rest
of the procedure.
For 1 drop = 20 or 40 ppm Sodium Chloride
1. Select sample size.
Desired Equivalence Sample Size
1 drop = 20 ppm 20.5 mL sample
1 drop = 40 ppm 10 mL sample
2. Rinse and fill 25 mL sample tube (#9198O) to desired
mark (Step 1) with water to be tested.
3. Add 1 drop R-0630 Chromate Indicator. Swirl to
mix. Sample should turn yellow.
4. Add R-0706 Silver Nitrate Reagent dropwise,
swirling and counting after each drop, until color
changes from yellow to red. Always hold bottle in
vertical position.
NOTE: Do NOT add enough R-0706 Silver Nitrate Reagent
to give a brown color. First change from yellow
to red is the endpoint.
5. Multiply drops of R-0706 Silver Nitrate Reagent by
desired equivalence factor (Step 1). Record as
parts per million (ppm) salt as sodium chloride.
For 1 drop = 100, 200, or 800 ppm Sodium Chloride
1. Select sample size.
Desired Equivalence Sample Size
1 drop = 100 ppm 4 mL sample (2 x 2 mL)
1 drop = 200 ppm 2 mL sample
1 drop = 800 ppm 0.5 mL
2. Using a 3 mL pipet (#4078), add desired sample size
(Step 1) to 25 mL sample tube (#9198O). Dilute to
10 mL mark with distilled, deionized, or tap water.
3. Add 1 drop R-0630 Chromate Indicator. Swirl to
mix. Sample should turn yellow.
4. Add R-0706 Silver Nitrate Reagent dropwise,
swirling and counting after each drop, until color
changes from yellow to red. Always hold bottle in
vertical position.
NOTE: Do NOT add enough R-0706 Silver Nitrate Reagent
to give a brown color. First change from yellow
to red is the endpoint.
5. Multiply drops of R-0706 Silver Nitrate Reagent by
desired equivalence factor (Step 1). Record as
parts per million (ppm) salt as sodium chloride.
This product ships within approx. 5 to 7 business days from the state of Maryland. Listed below is the shipping transit time for 2024. UPS transit map - This product only ships UPS. We can not ship this product via Fedex or USPS.
- We can ship internationally.
- We can not ship this product to a PO box.
- If the product is Haz mat. It can not can not ship this via Air.
You will receive the tracking info after the order ships within 48 to 72 hours. We do not offer expedited shipping for this product.
If you can not order online, call in your order at 800-658-7716.
|
|
|
|
|
|
|