DROP TEST SODIUM NITRITE (1 drop = 40 ppm)
COMPONENTS:
1 x 5011 Instruction
1 x 9198R Sample Tube, Graduated, 25 mL, plastic
w/cap and red dot
1 x R-0819-C Ferroin Indicator, 2 oz, DB
2 x R-0820-C CAN Solution, 2 oz, DB 1. Rinse and fill sample tube (#9198R) to 5 mL
mark with cooled (room temperature) water to be
tested.
2. Add 4 drops R-0819 Ferroin Indicator. Swirl to
mix. Sample should turn red (orange).
3. Add R-0820 CAN Solution dropwise, swirling and
counting after each drop, until color changes from
red (orange) to blue. Always hold bottle in
vertical position.
4. Multiply drops of R-0820 CAN Solution by 40. Record
as parts per million (ppm) sodium nitrite.
NOTE: For results as nitrite, multiply sodium nitrite
concentration by 0.67.
DROP TEST PHOSPHONATE EQUIVALENCE (PPM)
ATMP (1.0); Na5ATMP(1.3); HEDP (0.9); K6HDTMP (1.2); DTPMP (1.45), Na5DTPMP (1.7)
COMPONENTS:
1 x 5051 Instruction
1 x 9198P Sample Tube, Graduated, 25 mL, plastic w/cap
and purple dot
1 x 9315 Test Paper, pH, 1.8-3.8
1 x R-0686P-C Sulfuric Acid N (purple cap), 2 oz, DB
1 x R-0697-C Thiosulfate N/10, 2 oz, DB
1 x R-0802P-I XO Indicator Powder, 10 g
1 x R-0803-C Phosphonate Titrating Solution, 2 oz, DB
1 x R-0805-C Fluoride Masking Agent, 2 oz, DB.
NOTE: Iron can cause negative interference at a level greater
than 5 ppm.
Orthophosphate and polyphosphate can cause
positive interference at all levels.
NOTE: Run a blank using tap water. Normal blank
requires about 2 drops of R-0803 Phosphonate Titrating
Solution to reach endpoint.
1. Rinse and fill 25 mL sample tube (#9198P) to 25 mL
mark with water to be tested.
2. Add:
1 drop R-0697 Thiosulfate N/10
10 drops R-0805 Fluoride Masking Agent
1 level dipper R-0802P XO Indicator Powder
Swirl to mix.
3. Adjust pH between 2.6 and 3.0:
Add 1 drop R-0686P Sulfuric Acid N. Swirl to mix.
Dip test paper (#9315) into sample, in direction of
arrow, for 3 seconds, with all color zones immersed.
Match indicator zone (unnumbered square between 2.7
and 3.0 color standards) with color scale. Read printed
pH value. If necessary, continue adding R-0686P Sulfuric
Acid N dropwise, swirling and checking pH with a new test
paper after each drop, until a pH between 2.6 and 3.0 is
obtained. Sample should be yellow.
4. Add R-0803 Phosphonate Titrating Solution dropwise,
swirling and counting after each drop, until color changes
from yellow to purple-pink. Always hold bottle in
vertical position.
5. Subtract drops of R-0803 Phosphonate Titrating Solution in
blank from drops in sample (Step 4). Multiply
by appropriate conversion factor (see CONVERSION FACTORS).
Record as parts per million (ppm) phosphonate.
DROP TEST TOTAL HARDNESS (1 drop = 10 ppm)
COMPONENTS:
1 x 5202 Instruction
1 x 9198B Sample Tube, Graduated, 25 mL, plastic w/cap
and blue dot
1 x R-0619B-C Hardness Buffer (blue cap), 2 oz, DB
1 x R-0620B-I Hardness Indicator Powder (blue cap), 10 g
1 x R-0683-C Hardness Reagent, 2 oz, DB
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE
800-TEST KIT (800-837-8548).
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT
LABELS. KEEP REAGENTS AWAY FROM CHILDREN.
1. Rinse and fill 25 mL sample tube (#9198B) to 25 mL
mark with water to be tested.
NOTE: For results in grains per gallon (gpg), fill to
14.6 mL mark.
2. Add 5 drops R-0619B Hardness Buffer. Swirl to mix.
3. Add 1 dipper R-0620B Hardness Indicator Powder.
Swirl until dissolved. If hardness is present,
sample will turn red.
4. Add R-0683 Hardness Reagent dropwise, swirling and
counting after each drop, until color changes from
red to blue. Always hold bottle in vertical
position.
5. Multiply drops of R-0683 Hardness Reagent by 10.
Record as parts per million (ppm) total hardness as
calcium carbonate.
NOTE: For 14.6 mL sample, record drops as grains per
gallon (gpg) total hardness as calcium carbonate.
DROP TEST SODIUM SULFITE (1 drop = 10 ppm)
COMPONENTS:
1 x 5203 Instruction
1 x 9198W Sample Tube, Graduated, 25 mL, plastic w/cap
and white dot
1 x R-0699-C Iodide Iodate Reagent, 2 oz, DB
1 x R-0638W-C Phenolphthalein Indicator (white cap),
2 oz, DB
1 x R-0725-I Acid Starch Indicator Powder, 10 g.
1. Collect water to be tested in a clean, preferably
large-mouthed, bottle to overflowing. Immediately
cap and cool to room temperature.
2. Rinse and fill 25 mL sample tube (#9198W) to 25 mL
mark with cooled (room temperature) water to be tested.
NOTE: For results in grains per gallon (gpg), fill to
14.6 mL mark.
3. Add 1 drop R-0638W Phenolphthalein Indicator. Swirl
to mix. Sample should turn red.
4. Add R-0725 Acid Starch Indicator Powder, a dipper at
a time, swirling after each dipper, until color
changes from red to colorless. Add 2 more dippers.
Swirl until dissolved.
5. Add R-0699 Iodide Iodate Reagent dropwise, swirling
and counting after each drop, until color changes
from colorless to a faint but permanent blue.
Always hold bottle in vertical position.
6. Multiply drops of R-0699 Iodide Iodate Reagent by
10. Record as parts per million (ppm) sodium
sulfite. For 14.6 mL sample, record drops as
grains per gallon (gpg) sodium sulfite.
DROP TEST CHLORIDE (1 drop = 10 ppm)
COMPONENTS:
1 x 5212C Instruction
1 x 9198O Sample Tube, Graduated, 25 mL, plastic
w/cap and orange dot
1 x R-0630-C Chromate Indicator, 2 oz, DB
1 x R-0638O-A Phenolphthalein Indicator (orange cap),
.75 oz, DB
1 x R-0706-C Silver Nitrate Reagent, 2 oz, DB
1 x R-0736O-C Sulfuric Acid .6N (orange cap), 2 oz, DB.
NOTE: When sulfite content of sample water to be tested
exceeds 10 ppm, the sulfite should be oxidized to
prevent interference in test. A 25 mL sample is
first adjusted to the appropriate pH, then 1 mL
(or 24 drops) of R-0649 3% Hydrogen Peroxide
Solution (sold separately) is added and thoroughly
mixed. Continue with the rest of the procedure.
1. Rinse and fill 25 mL sample tube (#9198O) to 25 mL
mark with water to be tested.
NOTE: For results in grains per gallon (gpg), fill to
14.6 mL mark.
2. Add 2 drops R-0638O Phenolphthalein Indicator. If
colorless--proceed to Step 3. If red, add R-0736O
Sulfuric Acid .6N dropwise, swirling after
each drop, until color changes from red to
colorless.
3. Add 5 drops R-0630 Chromate Indicator. Swirl to
mix. Sample should turn yellow.
4. Add R-0706 Silver Nitrate Reagent dropwise,
swirling and counting after each drop, until color
changes from yellow to a milky salmon (brick) red.
Always hold bottle in vertical position.
NOTE: Do not add enough R-0706 Silver Nitrate Reagent
to give a brown color. First change from yellow
to a milky salmon (brick) red is the endpoint.
5. Multiply drops of R-0706 Silver Nitrate Reagent by
10. Record as parts per million (ppm) chloride.
For 14.6 mL sample, record drops as grains per
gallon (gpg) chloride.
DROP TEST P/T ALKALINITY (HCl) (1 drop = 10 ppm)
COMPONENTS:
1 x 5229 Instruction
1 x 9198G Sample Tube, Graduated, 25 mL, plastic w/cap
and green dot
1 x R-0638G-A Phenolphthalein Indicator (green cap),
.75 oz, DB
1 x R-0645-C Total Alkalinity Indicator, 2 oz, DB
1 x R-0724-C Hydrochloric Acid .12N, 2 oz, DB.
1. Rinse and fill 25 mL sample tube (#9198G) to 25 mL
mark with water to be tested.
NOTE: For results in grains per gallon (gpg), fill to
14.6 mL mark.
2. Add 3 drops R-0638G Phenolphthalein Indicator.
Swirl to mix. Sample will turn pink if P
alkalinity is present--proceed to Step 3. If
colorless, go to Step 4.
3. If pink, add R-0724 Hydrochloric Acid .12N dropwise,
swirling and counting after each drop, until color
changes from pink to colorless. Record drops as P
reading. Always hold bottle in vertical position.
4. Add 5 drops R-0645 Total Alkalinity Indicator.
Swirl to mix. Sample should turn green.
5. Add R-0724 Hydrochloric Acid .12N dropwise,
swirling and counting after each drop, until color
changes from green to red. Record total drops
(Steps 3 and 5) as T reading. Always hold bottle in
vertical position.
6. Multiply P reading by 10. Record as parts per
million (ppm) P alkalinity as calcium carbonate.
Multiply T reading by 10. Record as ppm T
alkalinity as calcium carbonate. For 14.6 mL
sample, record P reading as grains per gallon (gpg)
P alkalinity as calcium carbonate. Record T
reading as gpg T alkalinity as calcium carbonate.
This product ships within approx. 5 to 7 business days from the state of Maryland. Listed below is the shipping transit time for 2024. UPS transit map - This product only ships UPS. We can not ship this product via Fedex or USPS.
- We can ship internationally.
- We can not ship this product to a PO box.
- If the product is Haz mat. It can not can not ship this via Air.
You will receive the tracking info after the order ships within 48 to 72 hours. We do not offer expedited shipping for this product.
If you can not order online, call in your order at 800-658-7716.
|
|
|
|
|
|
|