DROP TEST P/M OR P/T ALKALINITY (1 drop = 10 or 50 ppm)
COMPONENTS:
1 x 5084 Instruction
1 x 9198G Sample Tube, Graduated, 25 mL, plastic w/cap
and green dot
*1 x R-0637-C Methyl Orange Indicator, 2 oz, DB
1 x R-0638G-C Phenolphthalein Indicator (green cap), 2 oz, DB
*1 x R-0645-C Total Alkalinity Indicator, 2 oz, DB
1 x R-0687G-C Sulfuric Acid .12N (green cap), 2 oz, DB
1 x R-0736G-C Sulfuric Acid .6N (green cap), 2 oz, DB
*Kit contains only one of these indicators.
P/M Alkalinity
NOTE:
For 1 drop = 10 ppm, use R-0687G Sulfuric Acid .12N.
For 1 drop = 50 ppm, use R-0736G Sulfuric Acid .6N.
1. Rinse and fill 25 mL sample tube (#9198G) to 25 mL
mark with water to be tested.
NOTE: For results in grains per gallon (gpg), fill to
14.6 mL mark.
2. Add 3 drops R-0638G Phenolphthalein Indicator.
Swirl to mix. Sample will turn pink if P
alkalinity is present--proceed to Step 3. If no
pink color, go to Step 4.
3. If pink, add R-0687G Sulfuric Acid .12N or R-0736G
Sulfuric Acid .6N dropwise, swirling and counting
after each drop, until color just changes from pink
to colorless. Record drops as P reading. Always
hold bottle in vertical position.
4. Add 3 drops R-0637 Methyl Orange Indicator. Swirl
to mix. Sample should turn yellow.
5. Continue adding R-0687G Sulfuric Acid .12N or R-0736G
Sulfuric Acid .6N dropwise, swirling and counting
after each drop, until color just changes from
yellow to orange (salmon pink). Record total drops
(Steps 3 and 5) as M reading. Always hold bottle in
vertical position.
6. If R-0687G Sulfuric Acid .12N was used, multiply P
reading by 10. Record as parts per million (ppm) P
alkalinity as calcium carbonate. Multiply M
reading by 10. Record as ppm M alkalinity as
calcium carbonate. For 14.6 mL sample, record P
reading as grains per gallon (gpg) P alkalinity as
calcium carbonate. Record M reading as gpg M
alkalinity as calcium carbonate.
If R-0736G Sulfuric Acid .6N was used, multiply P
reading by 50. Record as parts per million (ppm)
P alkalinity as calcium carbonate. Multiply M
reading by 50. Record as ppm M alkalinity as
calcium carbonate. For 14.6 mL sample, multiply P
reading by 5. Record as grains per gallon (gpg) P
alkalinity as calcium carbonate. Multiply M
reading by 5. Record as gpg M alkalinity as
calcium carbonate.
P/T Alkalinity
NOTE:
For 1 drop = 10 ppm, use R-0687G Sulfuric Acid .12N.
For 1 drop = 50 ppm, use R-0736G Sulfuric Acid .6N.
1. Rinse and fill 25 mL sample tube (#9198G) to 25 mL
mark with water to be tested.
NOTE: For results in grains per gallon (gpg), fill to
14.6 mL mark.
2. Add 3 drops R-0638G Phenolphthalein Indicator.
Swirl to mix. Sample will turn pink if P
alkalinity is present--proceed to Step 3. If no
pink color, go to Step 4.
3. If pink, add R-0687G Sulfuric Acid .12N or R-0736G
Sulfuric Acid .6N dropwise, swirling and counting
after each drop, until color just changes from pink
to colorless. Record drops as P reading. Always
hold bottle in vertical position.
4. Add 5 drops R-0645 Total Alkalinity Indicator.
Swirl to mix. Sample should turn green.
5. Continue adding R-0687G Sulfuric Acid .12N or R-0736G
Sulfuric Acid .6N dropwise, swirling and counting
after each drop, until color changes from green to
red. Record total drops (Steps 3 and 5) as T
reading. Always hold bottle in vertical position.
6. If R-0687G Sulfuric Acid .12N was used, multiply P
reading by 10. Record as parts per million (ppm) P
alkalinity as calcium carbonate. Multiply T
reading by 10. Record as ppm T alkalinity as
calcium carbonate. For 14.6 mL sample, record P
reading as grains per gallon (gpg) P alkalinity as
calcium carbonate. Record T reading as gpg T
alkalinity as calcium carbonate.
If R-0736G Sulfuric Acid .6N was used, multiply P
reading by 50. Record as parts per million (ppm) P
alkalinity as calcium carbonate. Multiply T
reading by 50. Record as ppm T alkalinity as
calcium carbonate. For 14.6 mL sample, multiply P
reading by 5. Record as grains per gallon (gpg) P
alkalinity as calcium carbonate. Multiply T
reading by 5. Record as gpg T alkalinity as
calcium carbonate.
This product ships within approx. 5 to 7 business days from the state of Maryland.
Listed below is the shipping transit time for 2024. UPS transit map - This product only ships UPS. We can not ship this product via Fedex or USPS.
- We can ship internationally.
- We can not ship this product to a PO box.
- If the product is Haz mat. It can not can not ship this via Air.
You will receive the tracking info after the order ships within 48 to 72 hours. We do not offer expedited shipping for this product.
If you can not order online, call in your order at 800-658-7716.
|
|
|
|
|
|
|