#1 in Distributing Specialty
Chemicals & Equipment

Email Us Today Free shipping on
all chemicals (48 states)

  Home > Cooling Water Chemicals >

Cooling Tower Chemical (Highly Corrosive Water) - 5 to 55 Gallons
Corrosive Water Conditions Treatment - 5 to 55 Gallons
Highly Corrosive Water Conditions Treatment - 5 to 55 Gallons
 
Alternative Views:


Chemworld 1206 - 5 to 55 Gallons
Our Price: $349.99
Sale Price: $289.99
Savings: $60.00


Quantity in Stock:24

Free Shipping
Availability: Usually Ships in 3 to 5 Business Days
Product Code: CW1206


ChemWorld 1206*:


Drum Delivery Option*:


Qty:
Description Shipping & Transit Times
 

Corrosive Tower Water Conditions

ChemWorld 1206 is for severe corrosion waters. ChemWorld 1206 is a treatment program for open, recirculating cooling water systems that was optimized for corrosion and scale control. The product contains a combination of phosphonates, phosphate, polymeric dispersants and azole that provides system protection under severely corrosive operating conditions.This product does not contain a molybdate tracer.

  • This product is controlled and fed based on organophosphonate.
  • Maintain organophosphonate residual between 10 to 15 ppm in the cooling water with a organophosphonate test kit.
  • Feedrates: 120 to 240 ppm.
  • Uses roughly 1.1 to 2.2 gallons per 10,000 gallons of fresh makeup water.
What are the corrosion and scaling control chemicals in this blended product?
This chemical is a mixture of the below chemicals:
  • Potassium Hydroxide (Cas No.1310-58-3)
  • Potassium Phosphate (Cas No. 7778-53-2)
  • Sodium Tolytriazole (Cas No. 64665-57-2)
  • Potassium PolyPhosphate (Cas No. 7320-34-5)
  • Polyacrylate TerPolymer, Sodium Salt (Cas No. PROPRIETARY)
  • 2-Phosphonobutane-1 2,4- TriCarboxylic Acid, Potassium Salt (Cas No. 3858-78-7)
For new cooling tower startups, consider our ChemWorld 101 Cooling Startup Kit. This kit includes the following:
  • One 5 gallon pail of ChemWorld Q-ALK-PC - This product is required to clean the debris and greases prior to startup.
  • One 5 gallon pail of ChemWorld 1334 - ChemWorld 1334 is scale and corrosion control cooling tower chemical. After startup, you can perform testing of your water hardness and alkalinity and we can tune in your exact chemical for long-term protection.
  • One 5 gallon pail of ChemWorld 56 - ChemWorld 56 is a 12.5% sodium hypochlorite product that is required to kill bacteria. This is the cheapest easiest product to get your system up and going, you can convert to tablets or a stabilized bromide product after startup.
  • One LakeWood 140 Cooling Tower Controller - You will need to set the controller to feed and bleed the cooling tower water to maximize cycles and to minimize chemical usage rates. An optional dual biocide water treatment can be implemented after startup. This is model 1239597 (which is board mounted unit that has the flow assembly on the left).
  • One 1167435 Cooling Tower Blowdown Valve (1" NPT) - This will be required when the cooling tower calls to release cooling tower water.
  • Two Stenner 45MHP10 Adjustable Head Pumps - One pump is required for the corrosion/ scale prevention chemical and for the biocide. Each pump is rated to 100 psi, which should be enough to feed the chemical into the system. The ideal spot to feed the chemical is into the return header of the cooling tower. These Stenner Pump kits come with chemical injection valves that will allow for quick injection of each chemical into the sidestream water loop that is used to monitor the cooling tower conductivity.
  • One complete CWTK-200 Cooling Water Treatment Test Kit. This kit contains every test you will need to set up and fine tune your water treatment program.
  • One Chemical Metal Test Station Cabinet - You need to keep your test kits and lo sheets in one clean location. This test kit is ideal for cooling towers. Items in the photo of test kit not included.

Share your knowledge of this product. Be the first to write a review »